John Astad considers the importance of Safety Data Sheets (SDS) and asks if they ask the right questions, and how stakeholders can manage the risk in the workplace if important fire and explosion data is lacking?

In the global workplace, identifying and evaluating the risk from combustible dust related fires and explosions supposedly begin with the information provided on Safety Data or Material Safety Data Sheets (SDS/MSDS). These essential documents provide essential hazard identification, information on ingredients, first aid measures, fire-fighting procedures, handling and storage information, exposure controls/personnel protection, physical and chemical properties, and so forth.

Yet vital combustible dust physical characteristics of ignition sensitivity and explosion severity is lacking in a majority SDS’s. So how do stakeholders manage the risk in the workplace if important fire and explosion data is lacking?

Physical Fire and Explosion Hazards


An important development in hazard communication amongst international trading partners is the United Nations Globally Harmonized System of Classification and Labelling of Chemicals (GHS). This system provides a universal method of communicating the potential health and physical hazards that chemicals pose in the workplace, during transportation, or consumer usage of chemical products. Yet unfortunately, harmonization in communicating the physical and chemical hazards of combustible dust is also deficient in the newly implemented United Nations GHS.

Additionally a major problem arises with materials that are not chemicals, such as wood, paper, food, etc that are not included in the GHS Safety Data Sheet hazard communication protocol. How are the physical hazards of potential combustible dust related fire and explosions suppose to be communicated to the workplace from these non-chemical substances? The problem is intensified with the requirement that the raw product manufacturer or importer must provide the physical property data in the initial preparation of the SDS.

Lifecycle Hazard Awareness

This is great at the initial stage of a raw product’s lifecycle. But what about later on in the lifecycle when a product manufacturer utilizes the raw product in the production process? The production process handles the combustible particulate solid and generates combustible dust in operations such as cutting, grinding, polishing, crushing, conveying, mixing, sifting or screening of materials.

Now all of a sudden the physical properties have changed from a raw bulk product with a minimal hazard to a substance that provides a potentially explosive atmosphere under the right conditions. All that is needed for a dust explosion in addition to the basic fire triangle is a rendezvous with confinement and suspension .Understanding the parameters to initiate a combustible dust flash fire or dust explosion is where the  SDS should come into the picture in managing the fire and explosion risk, but unfortunately does not.

Global Harmonization Deficiency

Back in April 2009, the USA Occupational Health and Safety Administration (OSHA) submitted a working document to the United Nations Committee of Experts on the Transport of Dangerous Goods on the Globally Harmonized System of Classification and Labeling of Chemicals. The document requested that the Sub-Committee of Experts on the Globally Harmonized System of Classification and Labelling form a conference committee in developing classification criteria for combustible dusts in the Safety Data Sheets.

Currently GHS recognizes combustible dust is a hazard by identifying dust in the SDS.  Solely identifying is not sufficient enough. The global workplace needs additional information such as guidance in fire-fighting measures, exposure controls/personnel protection, handling/storage, physical and chemical properties, etc.

Explosive Atmospheres

Additionally combustible dust needs to be classified like flammable liquids and gases, which also can present an explosive atmosphere in the global workplace. In the EU, the ATEX Directives (Appareils destinés à être utilisés en ATmosphères EXplosibles) already recognizes the explosive nature of combustible dust that have the same explosive severity as vapor cloud explosions. Yet communicating the risk amongst international trading partners is another story through the GHS Safety Data Sheets.

In the United States recognition of the fire and explosion hazards from combustible dust that have the potential of an explosive atmosphere is not on the same level of awareness as the ATEX Directives in the EU. Currently in the USA, there is no occupational health and safety regulation that specifically references combustible dust in the industrial setting. In contrast there is an OSHA Grain Facility Standard that was implemented back in the 1980’s that addresses combustible dust hazards in grain mills, feed mills, etc.

Rulemaking Process

Following the catastrophic 2008 Imperial Sugar Refinery dust explosion in Port Wentworth, Georgia OSHA began taking enhanced measures in addressing combustible dust in the manufacturing workplace. Currently OSHA is in a general industry combustible dust rulemaking process. An undisclosed source says that OSHA will announce next week in the Federal Register the Advanced Notice of Proposed Rulemaking (ANPRM) where stakeholders can comment in the development of the proposed general industry regulation.

On another front, concerning hazard communication, OSHA is proposing to modify
its existing Hazard Communication Standard (HCS) that includes Materiel Safety Data Sheets  to conform with the United Nations’ (UN) Globally Harmonized System of Classification and Labelling of Chemicals (GHS). Two weeks ago OSHA issued its proposed rule in the Federal Register concerning harmonization of its current Hazardous Communication System with GHS and will seek comments from stakeholders for a ninety day period.

In addition to proposing to the United Nations committee that combustible dust be classified in the GHS Safety Data Sheets its also seeking comments from stakeholders in the USA whether the interim coverage of combustible dust as an unclassified hazard in the GHS SDS is sufficient in communicating the risk throughout the workplace. Hopefully stakeholders will provide OSHA with a plethora of comments on this very complex issue of combustible dust related fires and explosion in the industrial workplace.

Conclusion

Presently all global manufacturing facilities are at risk with the deficient ignition sensitivity and explosion severity information not included in the Safety Data and Material Data Sheets. The only alternative in properly managing the risk proactively would be for plant owners and managers to have their combustible dust tested for minimum ignition temperature (MIT), minimum ignition energy (MIE), minimum explosive concentration (MEC), explosion severity, volume resistivity, etc. Solely relying on physical fire and explosion hazard data in the SDS or MSDS that the raw product manufacturer or importer provided at the top of the lifecycle is an accident waiting to happen.

Contact Info: John Astad-Director/Research Analyst
Combustible Dust Policy Institute

Office: 409-440-7185
john@combustibledust.com

Resources
Classification and Labeling of Chemicals (GHS).

Working Document ComDust GHS

 

Sign Up

For the latest news and updates from Hemmingfire.

Company Profiles

Angus Fire – global innovation in fire fighting

Angus Fire is a global leader in fire fighting technology with a long history of pioneering innovation. The company occupies a unique world position in the development and manufacture of fire hose, foam concentrates and fire fighting equipment.

Holmatro - Mastering Power

Holmatro Rescue Equipment develops, manufactures, sells and services high-pressure hydraulic, pneumatic and mechanical rescue equipment. With a comprehensive dealer network on all continents, manufacturing plants in the Netherlands (head office) and USA, and sales offices in China and UK, we supply our products and services to fire and rescue organizations all over the world.

Dr Sthamer - Hamburg: foam fights fire

Dr Sthamer – Hamburg, has been developing and manufacturing state-of-the art firefighting foams since the 1920’s. Having been founded in 1886 by Dr Richard Sthamer, we are still proudly owned and managed by the Sthamer family. Our base is still at the original site where we started in, on the banks of the Bille River in Hamburg Germany.

Calendar

Firetrade Asia & Middle East Firetrade Europe